    Swimming pool test

    1 / Clor test with DPD # 1 reagent

    1. Pour water into the test tube as small as the horizontal line
    2. Put 1 DPD into the tube
    3. Cover the test tube and turn it several times to allow the drug to dissolve. (15-35)
    4. Compare the color in the tube with the standard color for the result.

    2 / pH test (standard range from 7.2 ppm to 7.6 ppm)

    1. Pour water into the test tube as large as the top line.
    2. Add 1 drop of solution 4 and mix well.
    3. Add 5 drops of solution 2 and mix well, then compare the color of reagent with standard color to see the result.
    4. If the result is above 7.8 ppm, it may be acid demand with reagent number 3 but still use the water sample tested above. Check and balance total alkalinity (if necessary) before pH equalization.

    Try the Acid Demand (if pH is above 7.8).

    1. For each drop of solution 3, count the number of drops after each small time until the color of the test water reaches 7.6 ppm
    2. See the table of acid solution to use to add acid to the lake for the appropriate.

    4 / Test the total alkalinity

    1. Pour water into the test tube as large as the bottom line
    2. Add 1 drop of solution 4 and shake
    3. Add 2 drops of solution 5
    4. Dilute each drop of solution # 3 (shake well after each run) and count the droplets sufficiently to turn the color into either colorless or light yellow.
    5. Multiply the drop number 3 by 10 (eg 10 drops = 100 ppm) and refer to the attached instructions.

    LUMINATE ACID HCL SUPPLY (INCLUDED)

    USING HCL ACID TO REDUCE pH

    Note: Do not add more than 1 liter of HCL to 76,000 liters of water at the same time and for 4 to 6 hours interval.

    BALANCE OF TOTAL KNOWLEDGE

    THE IDEAL STANDARD FOR CHEMICALS IN SWIMMING POOL AND MASSAGE

    A GUIDE TO IMPROVING PRECIOUS WATER TREATMENT

    1. The water in the tank must be circulated before sampling. If you turn off the filter, just operate it for a few minutes.
    2. Thoroughly clean the test equipment two or three times before attempting to avoid the effects of the previous test.
    3. Take test sample at a depth of about 45cm below the water surface.
    4. Do not use water in the mouth of the pipe to return clean water. Because this water has been filtered and may have been treated with chlorine, it will be different from the water remaining in the tank.
    5. The test water temperature should be between 15 ° C and 27 ° C.
    6. Should try after sampling.
    7. Care should be taken that the water sample is taken, properly closed, and out of reach of light and outside temperature.
    8. Reagent must always be good and fresh. Change the reagents annually and store them in a dry place where there is no light. Do not swing the lid of the testers.
    9. Apply the test specimen on the test specimen.
    10. Do not switch test instruments.
    11. Strictly follow the instructions completely. If the request is 5 drops, we drip not less than no less.
    12. Place the reagent bottle vertically above the test device and drip it one at a time.
    13. Shake the sample thoroughly. Use the lid, not the finger, not shake when mixing, only turn in a circle, or slope up the tube several times.
    14. Read the results in good light. Keep the test equipment at eye level. Do not wear sunglasses or read the sun rays immediately.
    15. Do not return the sample to the pond. Clean tools after washing.
    16. Keep the chemicals and reagents out of reach of children.

    IN ACCORDANCE WITH THE GUIDELINES AND USE OF GOOD AND VERY GOOD CHEMICALS FOR YOUR LIVING IN GREEN AND CLEAN